Hidden nose clip

of food aluminium inside half mask is adapted to any shape of nose

2

Innovative design

Ergonomic design in the form of a filtering face component

Large filtering surface area

is up to 240 cm2

Low breathing resistance

is provided by high performance ‘ELEFLEN’ material

1

Innovative design. Ergonomic design in the form of a filtering face component. Large filtering surface area is up to 240 cm2. Low breathing resistance is provided by high performance ‘ELEFLEN’ material

Hidden nose clip of food aluminium inside half mask is adapted to any shape of nose

Soft nose plate

is resistant to many bendings and does not exert pressure on the nose bridge during the long-term usage

1

Ergonomic

plastic spacer retains half-mask shape during operation

2

The elastic construction

of the obturator repeats mimic facial movements, provides high-quality protection during operation

3

Strangulator

provides a snug fit of the half-mask to face, excluding contaminated air suction

5

Adjustable webbing cap

provides half-mask retention on the head, does not exert pressure the long-term usage

4

Soft nose plate is resistant to many bendings and does not exert pressure on the nose bridge during the long-term usage

Ergonomic plastic spacer retains half-mask shape during operation

The elastic construction of the obturator repeats mimic facial movements, provides high-quality protection during operation

Adjustable webbing cap provides half-mask retention on the head, does not exert pressure the long-term usage

Strangulator provides a snug fit of the half-mask to face, excluding contaminated air suction

Hidden nose clip

of food aluminium inside half mask is adapted to any shape of nose

3

Innovative design.

Ergonomic design in the form of a filtering face component

Large filtering surface area

is up to 240 cm2

Low breathing resistance

is provided by high performance ‘ELEFLEN’ material

1

The exhalation valve

removes hot and moist exhaled air from inside the half-masks, prevents the formation of condensation, and reduces the temperature level inside the half-mask space

3

Innovative design. Ergonomic design in the form of a filtering face component. Large filtering surface area is up to 240 cm2. Low breathing resistance is provided by high performance ‘ELEFLEN’ material

Hidden nose clip of food aluminium inside half mask is adapted to any shape of nose

The exhalation valve removes hot and moist exhaled air from inside the half-masks, prevents the formation of condensation, and reduces the temperature level inside the half-mask space

Soft nose plate

is resistant to many bendings and does not exert pressure on the nose bridge during the long-term usage

1

Ergonomic

plastic spacer retains half-mask shape during operation

2

The elastic construction

of the obturator repeats mimic facial movements, provides high-quality protection during operation

3

Strangulator

provides a snug fit of the half-mask to face, excluding contaminated air suction

5

Adjustable webbing cap

provides half-mask retention on the head, does not exert pressure the long-term usage

4

Soft nose plate is resistant to many bendings and does not exert pressure on the nose bridge during the long-term usage

Ergonomic plastic spacer retains half-mask shape during operation

The elastic construction of the obturator repeats mimic facial movements, provides high-quality protection during operation

Adjustable webbing cap provides half-mask retention on the head, does not exert pressure the long-term usage

Strangulator provides a snug fit of the half-mask to face, excluding contaminated air suction

Application and Instructions

Without exhalation valve

Standart Medicine 103 Protection factor 4

Standart Medicine 203Protection factor 12

Standart Medicine 303 Protection factor 50

With exhalation valve

 

Standart Medicine 213Protection factor 12

Standart Medicine 313Protection factor 50

The STANDART MEDICINE respirators are designed as more progressive analogs to formable and folding respirators, as well as medical half-masks of domestic and foreign production, surpassing them in functionality.
They are intended for:
  • Medical employees
  • Rescuers of the Ministry of Emergency Situations
  • Population during seasonal outbreaks or pandemic of flu and other airborne disease
Standart Medicine 103 (Without exhalation valve)

FFP1 NR

The virus spread prevention from sick people - "environmental protection from a human"
Standart Medicine 203 (Without exhalation valve) Standart Medicine 213 (With exhalation valve)

FFP2 NR

For users protection from the tuberculosis bacteria, the influenza virus and other airborne diseases - "human protection from the environment"
Standart Medicine 303 (Without exhalation valve) Standart Medicine 313 (With exhalation valve)

FFP3 NR

For protection against dangerous biological and radioactive aerosols - "human protection from the environment"

The advantages of STANDART MEDICINE™ respirator

  • The elastic construction of the obturator repeats mimic facial movements, provides high-quality protection during operation
  • Reliable fixation on the person's face excludes suction of contaminated air
  • Soft hypoallergenic ‘ELEFLEN’ material does not cause skin irritation
  • Vision field restriction is no more than 12%
  • Thermal resistance – is up to +70°С
  • Ignition resistance.
  • It withstands low temperatures - up to -30°С
  • Ultrasonic bonding of all components
  • Ecologically safe, no harmful substances are used
  • Excellent compatibility with other personal protective equipment (goggles, helmets)

THE RESPIRATORS SELECTION GUIDELINE:

Product designation Efficiency class Nominal Protection Factor * Type of health care facilities Production site, type of performed work The predominant harmful factor, which requires respiratory protection
Standart 103

FFP1

4 Inpatient facilities, health centers, clinics, community clinics, including ophthalmologic, oncological, urological hospitals Registration office, reception, hospital wards, warehouses of hospital linen, canteen Contact with patients and contaminated hospital linen
Standart 203, 213

FFP2

12 Medical treatment rooms, inhalatorias Medicinal drugs of III-IV class of hazard
Standart 203, 213

FFP2

12 Medicinal drugs of I-II class of hazard and antibiotics (such as ampicillin, aminazin, benzylpenicillin, oxacillin, streptomycin, cytostatic, antitumor antibiotics and narcotic analgesics)
Standart 303, 313

FFP3

50
Standart 203, 213

FFP2

12 Specialized hospitals, among them infectious, tubercular, narcological, psychiatric ones Registration office, reception, hospital wards, warehouses of hospital linen, canteen Contact with patients and blood products
Standart 303, 313

FFP3

50
Standart 203, 213

FFP2

12 Health centers, among them dermatovenerologic, oncologic and antituberculous dispensaries Medical treatment rooms, inhalatorias Medicinal drugs of I-II class of hazard and antibiotics (such as ampicillin, aminazin, benzylpenicillin, oxacillin, streptomycin, cytostatic, antitumor antibiotics and narcotic analgesics)
Standard 303, 313

FFP3

50
Standart 103

FFP1

4 Emergency medical treatment and blood donor centers Blood donor center Contact with patients and blood products
Standart 203, 213

FFP2

12
Standart 103

FFP1

4 Maternity and child welfare services Perinatal centre, women’s consultation clinic, maternity hospital Contact with patients
Standart 203, 213

FFP2

12
Note*. Nominal Protection Factor (NPF) - indicates how many times the used individual respiratory protective equipment (RPE) reduces the concentration of harmful aerosol. Half mask efficiency class is determined by characteristics of the used ‘ELEFLEN’ filtering material.

Certification

They are included into the State Register of Medical Equipment and Medical Products.

They passed a toxicological and hygienic examination and evaluation of the biological impact (pre-clinical trials) in the Institute of Macromolecular Compounds Chemistry, National Academy of Sciences of Ukraine (Kyiv).

They have successfully passed clinical trials at I.I. Mechnikov Regional Clinical Hospital, Dnipro, to evaluate the effectiveness and safety of the medical device during operation, determining the appropriateness of using half-masks in medicine.